    How to fix DHW tank sensor error (T8) in Atlantic 024122 Heat Pump?
    • A
      Alexis NguyenSep 8, 2025
      If there's an error with the DHW tank sensor (T8) in your Atlantic Heat Pump, it could be due to a short circuit, disconnected or cut off sensor, a defective sensor, or another error. Check the sensor connections or replace the defective sensor.
  • J
    Jeremy GarciaSep 10, 2025
    How to troubleshoot circuit 2 sensor error (T12) in Atlantic 024122?
    • H
      Holly WrightSep 10, 2025
      If there's an error with the circuit 2 sensor (T12) in your Atlantic Heat Pump, it could be due to a short circuit, disconnected or cut off sensor, a defective sensor, or another error. Check the sensor connections or replace the defective sensor.
  • C
    Calvin LevySep 12, 2025
    Why is room temperature missing in area 1 on my Atlantic Heat Pump?
    • A
      Andrew AvilaSep 12, 2025
      If the room temperature in area 1 is missing when the "room T° influence" function (No. 33) is activated on your Atlantic Heat Pump, it's likely that parameter 33 is used without a room unit, or the room unit is disconnected or absent. Ensure that the room unit is connected and operational.
  • J
    jameslloydSep 14, 2025
    Why is room temperature missing in area 2 on my Atlantic 024122?
    • C
      Chelsea SolomonSep 14, 2025
      If the room temperature in area 2 is missing when the "room T° influence" function (No. 53) is activated on your Atlantic Heat Pump, it's likely that parameter 53 is used without a room unit, or the room unit is disconnected or absent. Ensure that the room unit is connected and operational.
  • N
    Nichole PruittSep 15, 2025
    What causes circuit temperature 2 to exceed 55°C in Atlantic 024122?
    • Z
      Zachary GillespieSep 15, 2025
      If circuit temperature 2 is greater than 55°C in your Atlantic Heat Pump, a defective mixing valve might be the cause. Check and replace the defective mixing valve.
  • J
    John DouglasSep 18, 2025
    What to do if the 2e zone sensor is not configured on my Atlantic 024122 Heat Pump (if 2nd circuits kit)?
    • J
      Jessica ElliottSep 18, 2025
      If the 2e zone sensor is not configured, set the parameter 5700 to 2, 4 or 6.