Checking the display
Compressors with an Elektronikon® controller:
Control panel Elektronikon®
Check the display (2) regularly for readings and messages. The display normally shows the compressor
outlet pressure, while the status of the compressor is indicated by pictographs. Remedy the trouble if alarm
LED (7) is lit or flashes, see sections Shutdown warning or Shutdown.
The display (2) will show a service message if a service plan interval has been exceeded or if a service
level for a monitored component has been exceeded. The service LED is on (see section Service warning).
Carry out the service actions of the indicated plans or replace the component and reset the relevant timer.
Compressors with an Elektronikon® Graphic controller:
Control panel Elektronikon® Graphic
Check the display (2) regularly for readings and messages. The display normally shows the compressor
outlet pressure, while the status of the compressor is indicated by pictographs. Remedy the trouble if alarm
LED (7) is lit or flashes, see sections Shutdown warning, Shutdown.
Remedy the trouble if alarm LED (7) is lit or flashes, see section . The display (2) will show a service
message if a service plan interval has been exceeded or if a service level for a monitored component has
been exceeded. Carry out the service actions of the indicated plans or replace the component and reset the
relevant timer, see section Service menu.
Checking the oil level
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!