- 85 -
Circuit-breaker, 3ph., lower voltage
Number of poles (optional) 4 4
Thermal release It (thermal release is higher at 25°C) (optional) 152 A 160 A
Magnetic release Im (optional) 500 A 600 A
Circuit-breaker, 1ph.
Number of poles (optional) 3 4
Thermal release It (thermal release is higher at 25°C) (optional) 160 A 190 A
Magnetic release Im (optional) 500 A 600 A
Fault current protection
Residual current release IDn 0.030-30 A 0.030-30 A
Insulation resistance (optional) 10-100 kOhm 10-100 kOhm
Outlet sockets (optional) i) domestic
Following two socket configurations are available: 2p + PE
1. i + ii + iii + iv 16 A/230 V
2. i + ii + iii + iv + v
ii) CEE form
3p + N + PE
16 A/400 V
iii) CEE form
3p + N + PE
32 A/400 V
iv) CEE form
3p + N + PE
63 A/400 V
v) CEE form
3p + N + PE
63 A/400 V