EasyManua.ls Logo

ATN CX 12 - Load Control

ATN CX 12
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATOR AND SAFETY MANUAL
1NO0031EN-08
CX 12 - CX 15
37
5.2. LOAD CONTROL
The load is measured when the platform is in a stationary position.
When the maximum load capacity on the aerial work platform is exceeded, the corresponding
indicator lights on the control stations flash and an alarm sounds. The platform must be partially
unloaded until the alarm stops.
When elevating the platform from the stowed position, the platform stops at a height of
approximately 0.5 meter (intermediate position) enabling the load to be weighed. If the
maximum load capacity is exceeded, the alarm is triggered; the platform may be lowered to the
stowed position to be unloaded.
Various power cut-out levels can be configured when the alarm is triggered above the
intermediate position.
Mode 1:
- Power cut-out except for lowering from the ground control station.
Mode 2:
- Cut-out of all movements.