4 System Organization
© Copyright Reserved Autonics Co., Ltd. 41
4.7 Connect with GP Editor
Communication between PC and LP-S044 is available with serial communication.
Setting method is as below.
1st Enter system setting menu.
Touch left-upper point as default position of system setting menu.
2nd Select [SET ENVIRONMENT]- [PLC SETTING]..
3rd Check that CH2 configuraiton is as‘EDITOR’, and connected connection port with LP-
S044 is as ‘RS232C’.
If the configuration is not as ‘EDITOR’, touch (PROTOCOL) part and cofigure as
‘EDITOR’.
Touch this, it rotates in order as EDITOR → PRINTER → BARCODE →
MONITOR.
Touch (PORT) area to configure the connection port of LP-S044.
Touch this, it rotates in order as [RS422] and [RS232C].
To check baud rate, data bit, stop bit, parity, etc, touch the desired channel ‘CH1’ or ‘CH2’.
It is able to download and upload GP Editor content to LP-S044 only when the baud rate
between GP Editor and LP-S044 are configured as same.
4th Touch [Menu], current setting values are saved and it returns to previous menu.
Touch [Exit], current setting values are saved and it returns to user screen after
exiting system setting menu.