11 Repair and Check
86 © Copyright Reserved Autonics Co., Ltd.
11.2 Check
11.2.1 General check
The following table is for checking by every day/week.
Environment
Temperature
0 to 50℃
Adjust the ambient
temperature
Humidity 35 to 85%RH
Adjust the ambient
humidity
Vibration No vibration
Establish vibration
protection
Mounting status
of LP-S044
Check screw
loosening for bracket
It should be mounted without
a shaken.
Tight the screw.
Connection
status of
communication
cable
Check screw
loosening of
connection cable
Cable connection part
should be tightened.
Tight the screw.
Use the standard cable
Connection
status of I/O
connector
Check whether
connector locking or
not, check
connection of
connector.
Connection part for
connector should be
connected tightly.
Secure locking part.
Wire connect cable with
duct, etc.
11.2.2 Periodic check
The following table is for checking by every month.
Power voltage
Measure power
voltage
Within power voltage
specification
Change supply power
Battery
Battery remaining
status
Battery remaining 95% Change battery
Waterproof rubber
ring
Waterproof rubber
ring status
Waterproof rubber ring
should not be corroded.
Change waterproof
rubber ring
Water leak and
dusk proof
Water leak and
dusk proof status
There is no water leaking,
and no dust.
Establish water leak and
dust protection
Inflammability gas
Leak inflammability
gas
It should not be exposed
at inflammability gas.
Establish leak
inflammability gas
protection