Location Selection
Location of a water conditioning system is important.
The following conditions are required:
Level platform or floor.
Room to access equipment for maintenance and
adding regenerant (salt) to tank.
Ambient temperatures over 34
o
F (1
o
C) and below
120
o
F (49
o
C).
Water pressure below 120 psi (8.27 bar) and above
25 psi (1.7 bar).
In Canada the water pressure must be below
100 psi (6.89 bar).
Constant electrical supply to operate the controller.
Total minimum pipe run to water heater of ten feet
(three meters) to prevent backup of hot water into
system.
Local drain for discharge as close as possible.
Water line connections with shutoff or bypass
valves.
Must meet any local and state codes for site of
installation.
Valve is designed for minor plumbing
misalignments. Do not support weight of system on
the plumbing.
Be sure all soldered pipes are fully cooled before
attaching plastic valve to the plumbing.