BCM50 Hardware & Installation
NN40011-002 Issue 1.2 BCM50 Rls 6.0 43
Trunk
Type
Expansion Port 1
Default Line Numbers
Expansion Port 2
Default Line Numbers
E1
065-094
095-124
T1
065-088
095-118
PRI
065-087
095-117
BCM50 Power Supply
The BCM50 power supply is an external device that connects to the BCM50
units. You must have one power supply for each unit you have in your BCM50
system
An uninterruptible power supply (UPS) is an optional device that you connect
to your BCM50 system. The UPS provides battery backup for the BCM50
system to maintain continuous operation during power interruption or failure
conditions.
Note: For the UPS to function correctly, it must be connected before the
BCM50 system is powered up. If you connect a UPS to a running system, the
UPS does not function.
Connecting a Power Supply Using a UPS
1. Mount the UPS within 1.5 meters (5 feet) of the BCM50 units.
2. The UPS must be close enough to the BCM50 units that the power
supply can be connected to both the UPS and the BCM50 units.
3. Plug one end of the USB cable into the USB port on the UPS.
4. For information about the location of the ports on the UPS, refer to the
UPS documentation.
5. Plug the other end of the USB cable into the USB hub.
6. Plug one end of the second USB cable into the USB hub.
7. Plug the other end of the second USB cable into the USB port on the
main unit.