BCM50 Hardware & Installation
NN40011-002 Issue 1.2 BCM50 Rls 6.0 45
Power
Status
Description
LED status during Start up sequence
Solid yellow
Solid yellow
Power Applied to System
Solid yellow
Off
Power on self test (POST).
Solid yellow
Solid yellow
System initializing.
Solid green
Solid yellow
Kernel initialization or Safe
OS.
Solid green
Flashing green
Services initializing.
Solid green
Solid green
Normal operation.
Solid green
Solid red
Services initialization failed.
LED states seen during Safe Mode start up sequence
Solid red
Solid green
System running with factory
default settings enabled.
Solid red
Solid red
System running in Software
Reset mode
Solid red
Flashing yellow
System running in
Configuration Reset mode.
LED states seen during shut down sequence or failure
Solid green
Flashing yellow
Graceful shutdown in
progress
Off
Solid yellow
Graceful shutdown
completed
Solid red
Flashing yellow
Overheat detected. Thermal
shutdown completed
Solid red
Solid red
Power spike or Rail power
fluctuation detected.
Flashing red
Solid red
Rail Power fluctuation. Power
Monitor Shutdown completed
Solid yellow
Solid red
Power spike shutdown
completed (temperature and
Rail power ok).
Off
Off
No power, system is shut
down (power cable is
disconnected)
Start-up Profile LED states (seen only during initial system install or staging)
Flashing Yellow
Flashing Yellow
Start-up Profile executing
Solid Green
Solid Green
Start-up Profile successfully
applied.
Flashing Yellow
Flashing Red
Start-up Profile failure.
Once the BCM50 has booted up and the BCM power and status lights are
solid green, the system start up process can then be commenced. Please
refer to the BCM50 System Start Up Guide for further details.