43
5AFTER OPERATION
5.1 MAINTENANCE AND CLEANING
ALS
104
GB
5.1.2 Cleaning agents
Cleaning agents for rubber rollers:
– Roller cleaner, order number 98925.
If other cleaning agents are used, there is a
chance the rubber may corrode.
Cleaning agents for metal deflection rollers:
– Cleaning solvent, alcohol-based solvent,
isopropyl alcohol, spray for removing labels
Cleaning the unit’s housing:
– Commercially available neutral cleaning
liquid
WARNING!
Cleaning solvent, alcohol-based solvent and
isopropyl alcohol are highly inflammable!
£ Keep the cleaning agents, as well as any
used cleaning cloths, away from open
flames and other sources of ignition.
£ Do not smoke.
£ Observe the safety instructions on the
container.
CAUTION!
Unsuitable cleaning agents can cause
considerable damage to the unit!
£ Do not use any cleaning agent that could
damage or destroy the resin surface,
labelling, display, nameplates, electrical
components, etc. Observe the
instructions of the cleaning agent
manufacturer.
£ Do not use any abrasive or
plastic-corroding cleaning agents.
£ Do not use any acidic or alkaline
solutions.
5.1.3 Regular maintenance
The label dispenser is designed to be mainte-
nance-free. However, you should service the unit regu-
larly in order to ensure reliable long-term operating
results.
Depending on operating conditions, you should per-
form the following at least on a weekly basis:
£ The cleaning and maintenance work described
below.
Removing paper debris
£ Wipe the paper residue from the rollers and edges.
£ Clean the sensor lenses with a soft brush or cloth.