6OPERATIONAL FAILURES
6.1 ERROR MESSAGES
ALS
104
GB
6.1.1 Error messaging
Error messages are displayed as follows:
xxxxxxxxxxxxxxxx = Message text
At the same time, a signal is activated at the signal
output of the unit, which can be used to switch on an
external visual or audible signal.
£ Press the key to reset the error message.
Before considering applying any remedies, check
whether the message appears repeatedly:
£ Turn off the unit and switch it on again after 10
seconds.
– It is important to wait at least 10 seconds before
switching the unit back on again.
6.1.2 List of error messages
[54] Overview of numbered error messages.
xxxxxxxxxxxxxxxx
Reset Alarm?
No. Message text Possible cause Remedy
1 General Alarm – Motor failure
– Motherboard malfunction
£ Request a service technician
3 Missing Label – Max. number of missing label was
exceeded
£ Check the label material
4 Material Low Without a connected roll diameter check:
– The product sensor may have been
mistakenly connected to the socket for
the roll diameter check.
– Internal sensor connection cables may
be mixed up.
With a connected roll diameter check:
– The material roll has fallen short of the
critical diameter.
£ Connect the product sensor to the
correct socket.
£ Request a service technician.
£ Prepare to change the material roll.
5 Unknown Length The function LABEL SETUP > Label Size was
cancelled unsuccessfully.
– No label material inserted.
– Electronic fault.
£ Insert label material.
£ Request a service technician.