6OPERATIONAL FAILURES
6.1 ERROR MESSAGES
ALS
104
GB
6.1.1 Error messaging
Error messages are displayed as follows:
xxxxxxxxxxxxxxxx = Message text
At the same time, a signal is activated at the signal
output of the unit, which can be used to switch on an
external visual or audible signal.
£ Press the key to reset the error message.
Before considering applying any remedies, check
whether the message appears repeatedly:
£ Turn off the unit and switch it on again after 10
seconds.
It is important to wait at least 10 seconds before
switching the unit back on again.
6.1.2 List of error messages
[54] Overview of numbered error messages.
xxxxxxxxxxxxxxxx
Reset Alarm?
No. Message text Possible cause Remedy
1 General Alarm Motor failure
Motherboard malfunction
£ Request a service technician
3 Missing Label Max. number of missing label was
exceeded
£ Check the label material
4 Material Low Without a connected roll diameter check:
The product sensor may have been
mistakenly connected to the socket for
the roll diameter check.
Internal sensor connection cables may
be mixed up.
With a connected roll diameter check:
The material roll has fallen short of the
critical diameter.
£ Connect the product sensor to the
correct socket.
£ Request a service technician.
£ Prepare to change the material roll.
5 Unknown Length The function LABEL SETUP > Label Size was
cancelled unsuccessfully.
No label material inserted.
Electronic fault.
£ Insert label material.
£ Request a service technician.