D - BEGINNING OPERATION
3.1.1. OPERATING MODE (AUTOMATIC
CLOSING OR SEMI-AUTOMATIC
CLOSING)
This automatic gate opening mechanism has 3
operating modes.
Semi-automatic mode (mode 1, LED 1 on)
(default)
Closed gate -> one press on the gate command
(complete or partial) opens the gate.
Open gate -> one press on the gate command
(complete or partial) closes the gate.
While the gate is in motion, you can stop it by
pressing the (gate or pedestrian) command.
By pressing on the gate command again, the gate
swings in the opposite direction.
Automatic closing mode (mode 2, LED 1 and
2 on)
In this operating mode, you must connect the
photocells and they must be functional.
Closed gate -> one press on the gate command
(complete or partial opening) opens the gate,
which remains open for a certain time (adjustable
time, see “Time delay”), then closes automatically.
During the time delay, you can cancel the
automatic closure by pressing a command
(complete or partial). The gate stays open and
you must press the command to close the gate.
While the gate is in motion, you can stop it by
pressing a command (complete or partial).
By pressing on the command again, the gate
starts in the opposite direction.
Collective mode (mode 3, LED 1, 2 and 3 on)
This mode is used for a gate with collective
access. In this operating mode, you must connect
the photocells and they must be functional.
Closed gate -> pressing and releasing the gate
command once opens the gate, which remains
open for a certain time (adjustable time, see
“Time delay”), then closes automatically.
Unlike the automatic closure mode:
If you press a command during opening, it will not
be acknowledged.
If you press a command during the time delay,
instead of cancelling the automatic closure, the
time delay starts again at 0.
If you press a command during closure, the gate
shuts, opens again and starts the automatic
closure time delay.
Note: you can only control complete opening; the
partial opening command does not work.
To choose the operating mode, follow this
procedure:
Press on PROG 2 or 3 times and the green LED
should be switched on (only the green LED)
Press PROGfor 3 seconds. L0 will ash once
and L1 will turn on.
Press OK and the number of LEDs switched on
will then indicate the operating mode that has
already been set (mode 1 by default).
To change the operating mode, use the “+” and
“-” buttons, then conrm with the OK button.
N.B.: applicable regulations require the installation
of photocells for security during automatic closing.
3.1.2. TIME DELAY (FOR AUTOMATIC MODE)
The time delay is the time during which the gate
remains open before closing automatically (if
automatic closing is activated).
To adjust this value, follow this procedure:
Press on PROG 2 or 3 times and the green LED
should be switched on (only the green LED)
Press PROGfor 3 seconds. L0 will ash once
and L1 will turn on.
Press “+” once. L2 will turn on instead of L1.
Press OK”. The number of LEDs that turn on will
indicate the set value.
Use the “+” and “-” buttons to change this value
(see table below).
Press OK” to conrm this value. All the LEDs will
turn on and off to conrm the operation.