l
Optional IR illuminator ring (H4AMH-AD-IRIL1)
Pendant Mount Installation Steps
Complete the following sections to install the device.
(Optional) Installing the Pendant Wall Mount
Use the procedure below to install the pendant wall mount (WLMT-1001) for use with the H5A Multisensor
pendant mount adapter (H5AMH-AD-PEND1).
CAUTION — The dome camera must be mounted as instructed below or problems with moisture
may arise and will not be covered by the dome camera warranty.
1. Determine where the cables will enter the pendant wall mount.
l
If the cables will be pulled from inside the mounting surface, use the cable entry hole at the
rear of the pendant wall mount.
l
If the cables will be coming out of an external conduit pipe, use the 3/4” NPT pipe entry hole on
the bottom of the pendant wall mount.
2. Use the provided mounting template to drill four mounting holes into the mounting surface.
l
If you are using the rear cable entry hole, also drill the cable entry hole into the mounting
surface.
3. Pull the required cables through the preferred cable entry hole on the pendant wall mount.
l
If you are using the pipe entry hole, pull the cables through the pipe conduit then the wall
mount. Next, apply thread seal tape to the pipe conduit and screw it into the pipe entry hole.
4. Fasten the pendant wall mount to the mounting surface.
Pendant Mount Installation Steps 18