Resetting to Factory Default Settings
If the device no longer functions as expected, you can choose to reset the device to its factory default
settings.
Use the firmware revert button to reset the device. The firmware revert button is shown in the following
diagram:
Note: Be careful not to scratch the dome bubble.
1. Ensure the camera is powered on.
2. Remove the dome cover.
3. Using a straightened paperclip or similar tool, gently press and hold the firmware revert button (*) for
two seconds.
4. Re-install the dome cover.
CAUTION Do not apply excessive force. Inserting the tool too far may damage the camera.