4.2 Connection to Other Exhaust Gas Testers
(with Universal Adapter)
Connect the clamp-on transducer cable
The clamp-on transducer cable is mounted onto the AVL DiTEST Speed 2000 in 3 stages:
− First clamp the ground tongs onto the metal sleeve of the universal adapter (1)
− Then attach the clamp-on transducer cable to the flat plug of the universal adapter (2)
− Connecting the external power supply (3) EN0432
Fig. 4-2
In some cases, testers may need an extra ground connection between the
AVL DiTEST Speed 2000 (universal adapter) and the tester (tester's ground clamp).
Exhaust gas tester settings
Select the clamp-on transducer signal input on your exhaust gas tester.
Always follow the instructions in your exhaust gas tester manual!
4.3 Connection to Other Exhaust Gas Testers
(Using Trigger Clamp Bar)
• Plug the AVL Dual Sensor into the AVL DiTEST Speed 2000 and screw it in
• Connect the cable from the 12V plug-in power supply unit to the AVL DiTEST Speed 2000
• Clamp the trigger clamp of your exhaust gas tester to the trigger clamp bar of the
AVL DiTEST Speed 2000
• Exhaust gas tester settings
Select the speed measurement with the trigger clamp (1 ignition pulse per engine cycle).
Always follow the instructions in your exhaust gas tester manual!