2018-10-05 | Technical improvements, changes in design, printing- and other errors expected. 41
In the first device, the NIT is edited and uploaded to all devices. Subsequently, in the modulator output of the
first device, parameters such as the channel output frequency are changed. If the NIT is read in again, the old
channel output frequency will also be read in as it is still in device 2 and 3. Resetting removes all previous
loaded NIT configurations from the devices. These now only return their current configured settings while
reading.
Click RESET NIT.
The NIT entries of the devices are reset.