AXIS Q1602 Network Camera
System Options
Plain Cong
Plain Cong is for advanced users with experience of Axis product conguration. Most parameters can be set and modied from this
page. Help is available from the standard help pages.
To open Plain Cong, go to System Option s > Adva nc ed > Plain Cong.
Reset to Factory Default Settings
This will reset all parameters, including the IP addres s, to the factory default s ettings :
1. Disconnect power from the product.
2. Press and hold the Control button and reconnect power (see
Hardware Overview, on page 4
).
3. Keep the Control button pressed for about 15 seconds until the Status indicator ashes amber.
4. Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The
product has been reset to the factory d efault settings. The default IP address is 192.168.0.90
5. Re-assign the IP address.
6. Refocus the product.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.