86
DC output 2 Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 VDC
Max load = 50 mA
Configurable
(Input or
Output)
3–4 Digital input Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
0 to max 30 VDC
Digital output Internally connected to pin 1 (DC
ground) when active, and floating (unconnected) when
inactive. If used with an inductive load, e.g., a relay,
connect a diode in parallel with the load, to protect
against voltage transients.
0 to max 30 VDC, open
drain, 100 mA
Function Pin Notes Specifications
DC ground 1 0 VDC
DC output 2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 VDC
Max load = 50 mA
Configurable
(Input or
Output)
3–6 Digital input Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
0 to max 30 VDC
Digital output Internally connected to pin 1 (DC
ground) when active, and floating (unconnected) when
inactive. If used with an inductive load, e.g., a relay,
connect a diode in parallel with the load, to protect
against voltage transients.
0 to max 30 VDC, open
drain, 100 mA
Example:
1 DC ground
2 DC output 12 V, max 25 mA
3 Digital input
4 Digital output
AXIS Q8752-E Mk II Bispectral PTZ Network Camera