EasyManua.ls Logo

Baldor MintDrive II - Relay; General Purpose Output (X3); Serial RS232 Interface (X6); Serial RS485 Interface (X6)

Baldor MintDrive II
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.baldormotion.com
Specifications 8-9MN1901
8.1.11 Relay / general purpose output (X3)
All models Unit All models
Contacts Normally closed
Contact rating (resistive) 1A @ 30VDC
or
0.5A @ 125VAC
Maximum carrying current A 2
Maximum switching power 62.5A V, 30W
Maximum switching voltage 250VAC, 220VDC
Maximum switching current A 2
Capacitance
(between open contacts, at 1kHz)
pF 0.5
Update interval
Software (Mint programs)
DRIVEOKOUTPUT,
DRIVEENABLEOUTPUT,
GLOBALERROROUTPUT,
MOVEOUT, MOVEOUTX,
MOVEPULSEOUTX, PULSEOUTX
functions
PLC Task functions
Immediate
Equivalent to LOOPTIME:
1ms (default) or 2ms
Programmable
8.1.12 Serial RS232 interface (X6)
All models Unit All models
Signal RS232, non-isolated CTS/RTS
Bit rate Baud 9600, 19200, 38400, 57600
8.1.13 Serial RS485 interface (X6)
All models Unit All models
Signal 4-wire RS485, non-isolated
Bit rate Baud 9600, 19200
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Related product manuals