www.baldormotion.com
Specifications 8-9MN1901
8.1.11 Relay / general purpose output (X3)
All models Unit All models
Contacts Normally closed
Contact rating (resistive) 1A @ 30VDC
or
0.5A @ 125VAC
Maximum carrying current A 2
Maximum switching power 62.5A V, 30W
Maximum switching voltage 250VAC, 220VDC
Maximum switching current A 2
Capacitance
(between open contacts, at 1kHz)
pF 0.5
Update interval
Software (Mint programs)
DRIVEOKOUTPUT,
DRIVEENABLEOUTPUT,
GLOBALERROROUTPUT,
MOVEOUT, MOVEOUTX,
MOVEPULSEOUTX, PULSEOUTX
functions
PLC Task functions
Immediate
Equivalent to LOOPTIME:
1ms (default) or 2ms
Programmable
8.1.12 Serial RS232 interface (X6)
All models Unit All models
Signal RS232, non-isolated CTS/RTS
Bit rate Baud 9600, 19200, 38400, 57600
8.1.13 Serial RS485 interface (X6)
All models Unit All models
Signal 4-wire RS485, non-isolated
Bit rate Baud 9600, 19200
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baldor MintDrive II and is the answer not in the manual?

Baldor MintDrive II Specifications

General IconGeneral
BrandBaldor
ModelMintDrive II
CategoryServo Drives
LanguageEnglish

Related product manuals