MN1957 Input / Output 4-11
www.baldormotion.com
Figure 15: Digital input - typical connections from a Baldor FlexDrive
II
,
Flex+Drive
II
or MintDrive
II
NextMove ESB-2FlexDrive / equipment output
II
DIN4
USRV+
DOUT0
User
supply
24V
User
supply
GND
X9
X1
818
6
9
CREF1
NEC PS2562L-1
TLP280
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com