4-28 Input / Output MN1957
www.baldormotion.com
4.6 Connection summary - minimum system wiring
As a guide, Figure 30 shows an example of the typical minimum wiring required to allow the
NextMove ESB-2 and a single axis drive amplifier to work together. Details of the connector
pins are shown in Table 2.
Figure 30: Example minimum system wiring
+24V
0V
1
2
3
24V
control
supply
Common
earth/ground
Common
earth/ground
9
10
Serial or USB
connection
Encoder output from
drive (or motor)
Demand+
Enable
GND
USB
Drive amplifier
(axis0)
Host PC
NextMove ESB-2
X5
X1
X12
X13
Demand-
Servo Systems Co. • 115 Main Road • P.O. Box 97 • Montville, NJ,
07045-0097 • (973) 335-1007 • Toll Free: (800) 922-1103
Fax: (973) 335-1661 • www.servosystems.com