5-28 Operation MN1957
www.baldormotion.com
Figure 39: Correct value of KPROP
The two traces will probably appear with a small offset from each other, which represents the
following error. Adjust KPROP by small amounts until the two traces appear on top of each
other (approximately), as shown in Figure 39.
Note: It may be useful to use the zoom function to magnify the end point of the move.
In the graph area, click and drag a rectangle around the end point of the traces.
To zoom out, right-click in the graph area and choose Undo Zoom.
Measured position
Demand position