Handscanners
BCS 3600
ex
series
7 Connection /
commissioning (qualified
personnel)
Subject to technical modifications
17/05/18
47 / 72
7.2 Universal supply module
7.2.1 Establishing universal supply module connections
DANGER
Non-approved accessories!
Loss of function and risk of explosion.
Only use universal supply modules that have been specified for the relevant configuration by
BARTEC.
The approved accessories are shown in the system overview (see system overview, Chapter 15.2,
P. 70). The model is clearly indicated on the type label.
The universal supply module is mounted to a secure base.
1. When using the wired hand-held scanner: connect the connection cable of the hand-held
scanner to the universal supply module, turning the connection cable clockwise to screw tight.
2. When using the Bluetooth hand-held scanner: connect the hand-held scanner via pairing to the
universal supply module (see Chapter 6.4.1, P. 41).
3. Feed the connection cable for the power supply through the cable gland into the universal
supply module.
4. Feed the data cable between the PC and universal supply module through the cable gland into
the universal supply module.
5. Connect the connection cable for the power supply to the universal supply module according to
the terminal connection plan (see Chapter 4.6.1, P. 32).
6. Connect the data cable between the PC and universal supply module to the universal supply
module according to the terminal connection plan and interface type (see Chapter 4.6.1, P. 32).
7. Check connections and terminal assignments.
8. Connect data cable between the PC and universal supply module to the PC.
9. Set the DIP switch (see Chapter 4.6.2, P. 33 for configuration).
10. Close the cover of the universal supply module.
11. Connect the connection cable for the power supply to the power source.
12. For connection to an HID device or to a PLC: note further information on the interfaces (HID
device: see Chapter 7.2.2, P. 48; PLC: see Chapter 7.2.3, P. 48)

Table of Contents

Other manuals for Bartec BCS 3608ex-NI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bartec BCS 3608ex-NI and is the answer not in the manual?

Bartec BCS 3608ex-NI Specifications

General IconGeneral
BrandBartec
ModelBCS 3608ex-NI
CategoryScanner
LanguageEnglish

Related product manuals