Page #39 background image
9424200996 3-5
BE1-11m Controls and Indicators
If the switch is set to Pulse mode, only the “Pulse selection will function. If the switch is set to
Switch/Pulse mode, any of the selections will function.
5. Press the Edit pushbutton a second time and the switch will change to the selected position and
the Edit LED will go out. If you want to abort the editing session without changing any controls,
press the Reset pushbutton before you press the Edit pushbutton the second time. The Edit LED
will go out.
Resetting Functions
The Reset pushbutton is context sensitive. Its function is dependent upon the screen that is presently
being displayed. For example, pressing the Reset key when Targets screen is displayed will reset the
targets, but it will not reset the alarms, etc. It is necessary to scroll through the menu tree to the
appropriate alarm screen to reset an alarm. You are prompted for a username and password when using
the Reset key.
Display Setup
BESTCOMSPlus Navigation Path: Settings Explorer, General Settings, Front Panel HMI
HMI Navigation Path: Settings Explorer, Control, General Settings, Front Panel HMI
Front-panel display settings are described in the following paragraphs. The BESTCOMSPlus Front Panel
HMI screen is illustrated in Figure 3-3.
LCD Setup
The contrast of the front-panel LCD (liquid crystal display) can be adjusted to suit the viewing angle used
or compensate for environmental conditions. When Invert Display is enabled, the display is inverted to
have blue letters on a white background.
Sleep Mode Setup
A power saving feature, referred to as Sleep mode, will dim the front-panel LCD backlight when a front-
panel key is not pressed for more than the user settable time delay. Normal display operation is resumed
when any front-panel button is pressed. Sleep mode is enabled and disabled in BESTCOMSPlus.
Language Setup
The language can be set for English or Russian. Language changes will affect the front-panel LCD,
sequence of events, fault reports, oscillography reports, load profile, and web pages.
Screen Scrolling Setup
When Screen Scrolling is enabled, the front-panel summary screen will scroll through the list of Scrolling
Screen items. The Scroll Time Delay determines the scrolling speed. The Show Splash Screen setting
allows the splash screen to be shown or hidden from screen scrolling. When screen scrolling is enabled
and no screens are selected, the splash screen is displayed even if the Show Splash Screen setting is
disabled. Scrolling screen items can only be selected in BESTCOMSPlus.
Targets and alarms are automatically displayed on the front-panel LCD when they become active if on the
splash screen. After targets and alarms are reset, the BE1-11m returns to the main screen and begins
scrolling if scrolling is enabled. Press the RIGHT navigation key to access the menu when targets and
alarms are being displayed.