Instruction Manual Breathing Air Compressors
32
1. Filter cartridge 80100: Filter cartridge lifetime [hours]
Filling pressure p = 200 bar Mariner 320
Ambient temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
320
10 20 - 24 37 - 30
15 25 - 29 28 - 23
20 30 - 34 21 - 17
25 35 - 39 16 - 13
30 40 - 44 13 - 10
35 45 - 49 10 - 8
40 50 - 54 8 - 6
Filling pressure p = 300 bar Mariner 320
Ambient
temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
190
10 20 - 24 56 - 45
15 25 - 29 42 - 34
20 30 - 34 32 - 26
25 35 - 39 25 - 20
30 40 - 44 19 - 16
35 45 - 49 15 - 12
40 50 - 54 12 - 10
Filter cartridge 80100: Bottle fillings [number] mass of molecular sieve mMS [g] = 311
Ambient
temperature
tU [°C]
Temperature
of final
separator
tAb [°C]
Moisture
content of air,
100% satured
X [g/m
3
]
Volume of processed air
Va [m
3
]
at pressure p [bar]
Number of bottle fillings n
and bottle size
200 300 7 l 10 l 12 l
10 20 - 24 17,31 - 21,80 719 - 571 1078 - 856 513 - 408 359 - 285 299 - 238
15 25 - 29 23,07 - 28,79 539 - 432 809 - 648 385 - 309 270 - 216 225 - 180
20 30 - 34 30,40 - 37,63 409 - 331 614 - 496 292 - 236 205 - 165 171 - 138
25 35 - 39 39,65 - 48,64 314 - 256 471 - 384 224 - 183 157 - 128 131 - 107
30 40 - 44 51,21 - 62,41 243 - 199 364 - 299 174 - 142 121 - 100 101 - 83
35 45 - 49 65,52 - 79,28 190 - 157 285 - 235 136 - 112 95 - 78 79 - 65
40 50 - 54 83,08 - 99,85 150 - 125 225 - 187 107 - 89 75 - 62 62 - 52
Bottle filling volume VF [m
3
]
Bottle size at pressure p [bar]
l [ltr.] 200 300
7 1,4 2,1
10 2 3
12 2,4 3,6
Number of bottle fillings n=
processed volume of air / bottle filling volume = Va / VF
Bottle filling volume: VF [m
3
] = p [bar] x l [l] / 1000 [l/m
3
]
Volume of air wich can be processed: Va [m
3
] = 0,2 x mMS [g]
/ (X [g/m
3]
/ p [bar]) = 0,2 x p [bar] x mMS [g] / X [g/m
3
]
Lifetime of filter cartridge: tp [h] = Va [m
3
] / (Q [m
3
/min] x 60
[min/h])