Instruction Manual Breathing Air Compressors
33
2. Filter cartridge 80114: Filter cartridge lifetime [hours]
Filling pressure p = 200 bar Mariner 320
Ambient temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
320
10 20 - 24 28 - 22
15 25 - 29 21 - 17
20 30 - 34 16 - 13
25 35 - 39 12 - 10
30 40 - 44 9 - 8
35 45 - 49 7 - 6
40 50 - 54 6 - 5
Filling pressure p = 300 bar Mariner 320
Ambient
temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
320
10 20 - 24 42 - 33
15 25 - 29 32 - 25
20 30 - 34 24 - 19
25 35 - 39 18 - 15
30 40 - 44 14 - 12
35 45 - 49 11 - 9
40 50 - 54 9 - 7
Filter cartridge 80114: Bottle fillings [number] mass of molecular sieve mMS [g] = 233
Ambient
temperature
tU [°C]
Temperature
of final
separator
tAb [°C]
Moisture
content of air,
100% satured
X [g/m
3
]
Volume of processed air
Va [m
3
]
at pressure p [bar]
Number of bottle fillings n
and bottle size
200 300 7 l 10 l 12 l
10 20 - 24 17,31 - 21,80 538 - 428 808 - 641 385 - 305 269 - 214 224 - 178
15 25 - 29 23,07 - 28,79 404 - 324 606 - 486 289 - 231 202 - 162 168 - 135
20 30 - 34 30,40 - 37,63 307 - 248 460 - 372 219 - 177 153 - 124 128 - 103
25 35 - 39 39,65 - 48,64 235 - 192 353 - 287 168 - 137 118 - 96 98 - 80
30 40 - 44 51,21 - 62,41 182 - 149 273 - 224 130 - 107 91 - 75 76 - 62
35 45 - 49 65,52 - 79,28 142 - 118 213 - 176 102 - 84 71 - 59 59 - 49
40 50 - 54 83,08 - 99,85 112 - 93 168 - 140 80 - 67 56 - 47 47 - 39
Bottle filling volume VF [m
3
]
Bottle size at pressure p [bar]
l [ltr.] 200 300
7 1,4 2,1
10 2 3
12 2,4 3,6
Number of bottle fillings n=
processed volume of air / bottle filling volume = Va / VF
Bottle filling volume: VF [m
3
] = p [bar] x l [l] / 1000 [l/m
3
]
Volume of air wich can be processed: Va [m
3
] = 0,2 x mMS [g]
/ (X [g/m
3]
/ p [bar]) = 0,2 x p [bar] x mMS [g] / X [g/m
3
]
Lifetime of filter cartridge: tp [h] = Va [m
3
] / (Q [m
3
/min] x 60
[min/h])