Instruction Manual Breathing Air Compressors
37
3. Filter cartridge 062565: Filter cartridge lifetime [hours]
Filling pressure p = 200 bar Mariner 320
Ambient temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
320
10 20 - 24 98 - 78
15 25 - 29 73 - 59
20 30 - 34 56 - 45
25 35 - 39 43 - 35
30 40 - 44 33 - 27
35 45 - 49 26 - 21
40 50 - 54 20 - 17
Filling pressure p = 300 bar Mariner 320
Ambient
temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
190
10 20 - 24 147 - 116
15 25 - 29 110 - 88
20 30 - 34 83 - 67
25 35 - 39 64 - 52
30 40 - 44 50 - 41
35 45 - 49 39 - 32
40 50 - 54 31 - 25
Filter cartridge 062565: Bottle fillings [number] mass of molecular sieve mMS [g] = 812
Ambient
temperature
tU [°C]
Temperature
of final
separator
tAb [°C]
Moisture
content of air,
100% satured
X [g/m
3
]
Volume of processed air
Va [m
3
]
at pressure p [bar]
Number of bottle fillings n
and bottle size
200 300 7 l 10 l 12 l
10 20 - 24 17,31 - 21,80 1876 - 571 2815 - 2235 1340 - 1064 938 - 745 782 - 621
15 25 - 29 23,07 - 28,79 1408 - 432 2112 - 1692 1006 - 806 704 - 564 587 - 470
20 30 - 34 30,40 - 37,63 1068 - 331 1603 - 1295 763 - 617 534 - 432 445 - 360
25 35 - 39 39,65 - 48,64 819 - 256 1229 - 1002 585 - 477 410 - 334 341 - 278
30 40 - 44 51,21 - 62,41 634 - 199 951 - 781 453 - 372 317 - 260 264 - 217
35 45 - 49 65,52 - 79,28 496 - 157 744 - 615 354 - 293 248 - 205 207 - 171
40 50 - 54 83,08 - 99,85 391 - 125 586 - 488 279 - 232 195 - 163 163 - 136
Bottle filling volume VF [m
3
]
Bottle size at pressure p [bar]
l [ltr.] 200 300
7 1,4 2,1
10 2 3
12 2,4 3,6
Number of bottle fillings n=
processed volume of air / bottle filling volume = Va / VF
Bottle filling volume: VF [m
3
] = p [bar] x l [l] / 1000 [l/m
3
]
Volume of air wich can be processed: Va [m
3
] = 0,2 x mMS [g]
/ (X [g/m
3]
/ p [bar]) = 0,2 x p [bar] x mMS [g] / X [g/m
3
]
Lifetime of filter cartridge: tp [h] = Va [m
3
] / (Q [m
3
/min] x 60
[min/h])