38
4. Filter cartridge 067224: Filter cartridge lifetime [hours]
Filling pressure p = 200 bar Mariner 320
Ambient temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
320
10 20 - 24 81 - 65
15 25 - 29 61 - 49
20 30 - 34 46 - 37
25 35 - 39 35 - 29
30 40 - 44 27 - 23
35 45 - 49 21 - 18
40 50 - 54 17 - 14
Filling pressure p = 300 bar Mariner 320
Ambient
temperature
tU [°C]
Temperature of
final separator
tAb [°C]
Flow capacity
Q [l/min]
190
10 20 - 24 122 - 97
15 25 - 29 91 - 73
20 30 - 34 69 - 56
25 35 - 39 53 - 43
530 40 - 44 41 - 34
35 45 - 49 32 - 27
40 50 - 54 25 - 21
Filter cartridge 067224: Bottle fillings [number] mass of molecular sieve mMS [g] = 675
Ambient
temperature
tU [°C]
Temperature
of final
separator
tAb [°C]
Moisture
content of air,
100% satured
X [g/m
3
]
Volume of processed air
Va [m
3
]
at pressure p [bar]
Number of bottle fillings n
and bottle size
200 300 7 l 10 l 12 l
10 20 - 24 17,31 - 21,80 1560 - 1239 2340 - 1858 1114 - 885 780 - 619 650 - 516
15 25 - 29 23,07 - 28,79 1170 - 938 1756 - 1407 836 - 670 585 - 469 488 - 391
20 30 - 34 30,40 - 37,63 888 - 718 1332 - 1076 634 - 513 444 - 359 370 - 299
25 35 - 39 39,65 - 48,64 681 - 555 1021 - 833 486 - 396 340 - 278 284 - 231
30 40 - 44 51,21 - 62,41 527 - 433 791 - 649 377 - 309 264 -216 220 - 180
35 45 - 49 65,52 - 79,28 412 - 341 618 - 511 294 - 243 206 - 170 172 - 142
40 50 - 54 83,08 - 99,85 325 - 270 487 - 406 232 - 193 162 - 135 135 - 113
Bottle filling volume VF [m
3
]
Bottle size at pressure p [bar]
l [ltr.] 200 300
7 1,4 2,1
10 2 3
12 2,4 3,6
Number of bottle fillings n=
processed volume of air / bottle filling volume = Va / VF
Bottle filling volume: VF [m
3
] = p [bar] x l [l] / 1000 [l/m
3
]
Volume of air wich can be processed: Va [m
3
] = 0,2 x mMS [g]
/ (X [g/m
3]
/ p [bar]) = 0,2 x p [bar] x mMS [g] / X [g/m
3
]
Lifetime of filter cartridge: tp [h] = Va [m
3
] / (Q [m
3
/min] x 60
[min/h])

Table of Contents