EasyManua.ls Logo

Baumer TA202 User Manual

Baumer TA202
52 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
04.14
171.51.168/3
81005181
Irrtum sowie Änderungen in
Technik und Design vorbehalten.
Subject to modifcation in technic & design.
Inhalt
1 Allgemeines / Sicherheitshinweise
2 Systembeschreibung
2.1 Beschreibung
2.2 Blockdiagramm
3 Gerät anschliessen
3.1 Betriebsspannung anschliessen
3.2 Elektronische Ausgänge belegen
3.3 Signalausgänge belegen
3.4 Signaleingänge belegen
3.5 Sensorversorgung anschliessen
3.6 Schnittstellen anschliessen
3.7 Testroutine durchführen
4 Bedienerebene
5 Programmierebene
5.1 Drehzahl- / Geschwindigkeitsmessung
5.2 Berechnungsfunktionen
5.3 Zeitmessung
6 Technische Daten
6.1 Abmessungen
6.2 Werkseinstellungen
6.3 Fehlermeldungen
6.4 Programmierzeilen - Übersicht
7 Bestellbezeichnung
Baumer IVO GmbH & Co. KG
Dauchinger Strasse 58-62
DE-78056 Villingen-Schwenningen
Phone +49 7720 942-0
Fax +49 7720 942-900
www.baumer.com
info.de@baumerivo.com
Betriebsanleitung
Elektronischer Tachometer
TA202
Contents Seite / Page
General / Safety instructions 2 / 28
System description 4 / 30
Description 4 / 30
Block diagram 5 / 31
Connecting 6 / 32
Connecting the supply voltage 7 / 33
Assigning the electronic outputs 7 / 33
Assigning the signal outputs 8 / 34
Assigning the signal inputs 8 / 34
Connecting the sensor supply 8 / 34
Connecting the interfaces 9 / 35
Executing the test routine 10 / 36
Operating mode 11 / 37
Programming mode 12 / 38
Measuring speed and rpm 19 / 45
Measuring functions 20 / 46
Time measurements 20 / 46
Technical data 21 / 47
Dimensions 23 / 49
Default settings 24 / 50
Error messages 24 / 50
Programming lines - overview 25 / 51
Part number 26 / 52
Operating Instructions
Electronic tachometer
TA202
Question and Answer IconNeed help?

Do you have a question about the Baumer TA202 and is the answer not in the manual?

Baumer TA202 Specifications

General IconGeneral
Linearity± 0.1 % FSO
Resolution0.01 mm
Sampling Rate1 kHz
Protection ClassIP67
Power Supply24 V DC
Light SourceLaser diode
Operating Temperature-10°C to +50°C
OutputAnalog

Summary

Safety Instructions

General Information

General information about product development and safe operation.

Proper Use

Guidelines for correct application and operation of the device.

System Description

Device Description

Overview of the device's components and features.

LED Symbol Display

Explanation of the different LED indicators on the device.

Control Panel Overview

Description of the device's control buttons and their functions.

Block Diagram

Diagram illustrating the internal connections and signal flow.

Connecting the Device

Terminal Assignment

Detailed mapping of device terminals to their functions.

Connecting Supply Voltage

Instructions for connecting the AC and DC supply voltage.

Assigning Electronic Outputs

Configuration of the device's electronic output signals.

Assigning Signal Outputs (Relay Contacts)

Configuration of signal outputs using relay contacts.

Assigning Signal Inputs

Configuration of the device's signal input signals.

Connecting Sensor Supply

Instructions for connecting the sensor power supply.

Connecting Interfaces (Option)

Instructions for connecting serial interfaces like RS232, RS422, RS485.

Executing Test Routine

Procedure for running the device's built-in test routine.

Operating Mode

Read Tachometer Display F1

How to read the displayed value for tachometer F1.

Read Tachometer Display F2

How to read the displayed value for tachometer F2.

Measurement Function F3

How to read the displayed value for measurement function F3.

Read Max Hold Value

How to read the maximum stored value.

Limit Value P1

How to read the set limit value P1.

Limit Value P2

How to read the set limit value P2.

Programming Mode

1st Programming Field

Access and modification of all operating parameters.

2nd Programming Field

Disabling and enabling operating parameters for the operating level.

3rd Programming Field

Programming machine-related functions and interface parameters.

Key Functions Overview

Description of key assignments in operating and programming modes.

Programming Field 1 Details

Modification of individual values in the first programming field.

Programming Field 2 Details

Status selection for operating parameters.

Status Number Meanings

Explanation of status numbers 0, 1, and 2.

Modifying Parameter Status

Procedure for changing the status number of parameters.

Programming Field 3 Details

Programming machine-related functions and interface parameters.

Measurement Function Settings (F3)

Selection of measurement functions for display at F3.

Measurement Function Settings (0,1,2)

Specific measurement functions 0, 1, and 2.

F1 Signal Type and F2 Frequency

Configuration of signal type and frequency for F1 and F2.

Input Logic Configuration

Configuration of input signal logic (PNP/NPN).

Scale F1 for Speed Measurement

Setting the scale factor for F1 in speed measurement.

Scale F2 for RPM Measurement

Setting the scale factor for F2 in rpm measurement.

Scale F3 Multiplier Setting

Setting the scale factor for F3 (multiplier).

Update Time Configuration

Configuration of the display update time.

Time Out Settings (F1-F3)

Setting time-out behavior for measurement functions.

Time Unit Setting for F1

Setting the time unit for tachometer F1.

Time Unit Setting for F2

Setting the time unit for tachometer F2.

Max Hold Assignment

Assigning which display (F1, F2, F3) is used for Max hold.

Limit Value P1 Assignment

Assigning the type of value for limit P1.

Limit Value P2 Assignment

Assigning the type of value for limit P2.

Digital Output Logic

Configuring the logic for digital outputs (n.o./n.c. contacts).

Decimal Point Settings for F1, F2, F3

Setting the decimal point for displays F1, F2, and F3.

Basic Display Assignment

Setting the basic display after a reset or inactivity.

Code Setting for Programming

Setting or disabling the access code for programming.

Function Key F Assignment

Assigning a function to the F key for display changeover.

Lower Limit Value Output Behavior

Defining the behavior for the lower limit value output.

Baud Rate Configuration

Setting the data transmission rate for serial communication.

Parity Bit Configuration

Setting the parity bit for serial communication.

Stop Bit Configuration

Setting the stop bit for serial communication.

Device Address Setting

Setting the unique address for the device on a network.

Analog Output Assignment

Assigning which display value is outputted via analog.

Analog Output Offset

Setting an offset value for the analog output.

Lower Analog Limit Value

Setting the lower limit for the analog output.

Upper Analog Limit Value

Setting the upper limit for the analog output.

Measuring Speed and RPM

Decimal Places for Measurement

How to set decimal places for measurement display.

RPM Measurement Procedure

Procedure for measuring and displaying revolutions per minute (rpm).

Speed Measurement Procedure

Procedure for measuring and displaying speed (e.g., m/min).

Measurement Functions

Measurement Functions Description

Description of various measurement functions like ratio, differential, and extension/compression.

Time Measurement Functions

Functions and procedures for time-based measurements.

Path Run-through Time Measurement

Measuring the time taken to cover a specific path.

Start/Stop Signal Time Measurement

Time measurement initiated by start/stop input signals.

Period Duration Measurement

Measuring the duration between two sequential pulse flanks.

Pulse Duration Measurement

Measuring the duration of a pulse signal.

Pulse Rate Measurement

Measuring and displaying the rate of incoming pulses.

Technical Data

Electrical Ratings

Electrical specifications including voltage, power, and signal levels.

Mechanical Design Specifications

Physical specifications like dimensions, mounting, and material.

Trigger Level Specifications

Specifications for comparator inputs and relay outputs.

Electronic Output Specifications

Specifications for the electronic output signals.

Analog Output Specifications

Detailed specifications for the analog output.

Device Dimensions

Physical dimensions and cutout dimensions of the device.

Default Settings Overview

List of the device's factory default parameter settings.

Error Messages and Troubleshooting

Description of error codes and troubleshooting guidance.

Programming Lines Overview

A comprehensive overview of all programming lines and their default settings.

Part Number Configuration

Voltage Supply Options

Options for the device's voltage supply.

Output Options

Options for the device's output types.

Interface Options

Options for the device's communication interface.

Related product manuals