Planning of a safety-oriented control system
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Document no.: 5.09013.07
69
of 114
11
The determination of the required safety class (SIL, performance level) is carried out in
the scope of risk assessment. The course of action for the determination of the
Performance Level is described in DIN EN ISO 13849-1. Annex A of IEC 62061 contains
an
informative part for the determination of the required SIL.
11.2 Installation and wiring plan
An installation and wiring plan for the entire safety system is to be developed in the
planning phase. It contains all system components and their wiring.
CAUTION!
The applicable standards and guidelines on laying electrical lines are to be observed
wh
en developing the wiring plan.
11.3 Course of the planning phase
The system is planned according to the respective requirements of the plant or the
machine. The components available for the automation of the available components are
described in the Automation catalog of the company Baumüller Nürnberg GmbH. There,
you can find information on concepts, PLCs, fieldbuses, motion control, technology
blocks, HMIs, IPCs and I/Os.
Prior to commissioning of the Safety Module (SAF-001), the following has to be checked
an
d guaranteed:
m Compatibility of the Safety Module (SAF-001) with the converter (see chapter
ZCompatibility list SAF-001-000-xxxon page 38, ZCompatibility list SAF-001-001-
xxxon page 38 and ZCompatibility list SAF-001-000-002 with automatic restarton
page 39).
m Adequate supply of the converter by the connected power supply unit or safety
comp
onents.