TX-1xx Series Printer Operation Manual
~ 51 ~
example can be set to "Tare,Gross, Net" (note that "" is not included),
which means that the keyword for tare weight is "Tare", which contains the
data of the "Tare" string will be regarded as tare weight, and so on, the
gross weight keyword is "Gross", and the net weight keyword is "Net";
⚫ The case must be consistent with the output data of the scale;
⚫ Including the comma separator, the length of the keyword must not exceed
16 characters;
⚫ It is necessary to ensure that the keywords of tare, gross, and net weight are
unique in the data output by the scale, that is, they appear only once.
The printer does not limit the order of tare, gross, and net weight output from the
scale. After all the data are matched, the report is output.
The printer will check the data output from the scale, which is in accordance
with the formula: gross weight = tare weight + net weight, otherwise, the printer
will not accept the data.
After receiving the first matching data, the printer requires that all matching is
completed within 2 seconds, otherwise all matching results will be cleared and
restart matching, this means that the tare, gross, and net weight data output by
the scale must be completed within 2 seconds.