5-37. EVERY 3 CALENDAR YEARS
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. ____________________
FACILITY: _________________________________________
HELICOPTER S/N: __________________________________
REGISTRY NO.: ____________________________________
TOTAL TIME:______________________________________
SIGNATURE:_______________________________________
EMERGENCY FLOTATION SYSTEM
NOTE
This inspection applies to any reservoir/cylinder
which has been manufactured or last retested prior
to July 1, 2006
Chapter 99 1. Remove emergency flotation system nitrogen reservoir.
Perform a hydrostatic test in accordance with DOT-SP-8162
cylinder inspection.
26 JAN 2007 Rev. 15 Page 99/100