BHT-430-MM-2
5-00-00
26 JAN 2007 Rev. 15 Page 53
SCHEDULED INSPECTIONS
5-22. PROGRESSIVE INSPECTION — EVENT 7
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
DATE: __________________W.O. ____________________
FACILITY: _________________________________________
HELICOPTER S/N: __________________________________
REGISTRY NO.: ____________________________________
TOTAL TIME:______________________________________
SIGNATURE:_______________________________________
GENERAL:
Paragraph 5-13 1. Do a complete 50 hour inspection.
DETAIL:
Chapter 96 1. Remove the access panel from the aft electrical
compartment. Examine the condition of the electrical and
avionics components and make sure they are correctly
attached. Examine the electrical harnesses and cables for
frayed wires and loose or broken clamps and fasteners. (F4)
Chapter 96 2. Remove the battery. Examine the vent lines for blockage or
damage. Clean the battery area before you install a serviceable
battery. (F4)
NOTE
Examine inspection window(s) and sight glass(es)
for cracking and discoloration. If either of these
conditions are present the part must be removed and
replaced prior to returning helicopter for service.
Chapter 26 3. Examine the left and right engine fire bottles. Make sure
they show the correct pressure. (F3/F4)