18
1st
Digit
2nd
Digit
Diagnostic Code
Description
Possible Causes / Repair Information
J1587
(SID/
FMI)
J1939
(SPN/
FMI)
AuxiliaryDesignLanguage(ADL)&AuxiliaryI/Os
11 1
AuxiliaryI/OError–
AUXWL(#7)
•Checkforcorroded/damagedwiringorconnectorsbetweentheECU
andABSIndicatorLamp.
•CheckpinX1-5oftheECU‘Powerconnectorforthefollowing:
– Pin not pushed back.
–CorrectlywiredtotheABSIndicatorLamp(PinX1-5–supply)
– Shorted to ground, V
bat
orotherECUpins.
•VerifytheABSIndicatorLampisproperlygroundedandnotburnt
out.
After repairs — or if no issues are found — clear the diagnostic code.
If the diagnostic code persists, contact your local Bendix
representative before replacing the TABS‑6 Adv MC module.
152/12 612/12
11 2
AuxiliaryI/OError–
AUXI/O#1
•Checkforcorroded/damagedwiringorconnectorsbetweentheECU
and the auxiliary device.
•CheckPinsX2-1&X2-11oftheECU‘In-Out’(I/O)connectorforthe
following:
Pinsnotpushedback.
Correctlywiredtotheauxiliarydevice(PinX2-1–supply,pinX2-11
– ground)
Shortedtoground,V
bat
orotherECUpins.
Verify the auxiliary device is properly functioning and rated for
maximumloadof≤2amps.
After repairs — or if no issues are found — clear the diagnostic code.
If the diagnostic code persists, contact your local Bendix
representative before replacing the Bendix
®
TABS‑6
Adv MC
module.
152/12 612/12
11 3
AuxiliaryI/OError–
AUXI/O#2
•Checkforcorroded/damagedwiringorconnectorsbetweentheECU
and the auxiliary device.
•CheckPinsX2-2&X2-11oftheECU‘In-Out’connectorforthe
following:
Pinsnotpushedback.
Correctlywiredtotheauxiliarydevice(PinX2-2–supply,
PinX2-11–ground)
Shortedtoground,V
bat
orotherECUpins.
Verify the auxiliary device is properly functioning and rated for
maximumloadof≤2amps.
After repairs — or if no issues are found — clear the diagnostic code.
If the diagnostic code persists, contact your local Bendix
representative before replacing the TABS‑6 Adv MC module.
152/12 612/12
11 6
AuxiliaryI/OError–
AUXI/O#3
•Checkforcorroded/damagedwiringorconnectorsbetweentheECU
and the auxiliary device.
•CheckPinsX2-3&X2-12oftheECU‘In-Out’connectorforthe
following:
Pinsnotpushedback.
Correctlywiredtotheauxiliarydevice(PinX2-3–supply,pinX2-12
– ground)
Shortedtoground,V
bat
orotherECUpins.
Verify the auxiliary device is properly functioning and rated for
maximumloadof≤1.5amps.
After repairs — or if no issues are found — clear the diagnostic code.
If the diagnostic code persists, contact your local Bendix
representative before replacing the TABS‑6 Adv MC module.
152/12 612/12
Diagnostic Trouble Codes (DTCs) (continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BENDIX TABS-6 and is the answer not in the manual?

BENDIX TABS-6 Specifications

General IconGeneral
TypeTrailer ABS Module
Operating Temperature Range-40°C to +85°C
Protection RatingIP67
CategoryAutomobile Accessories
Voltage12V/24V
CommunicationJ1587/J1939
MountingFrame Mount
ManufacturerBENDIX
System TypeABS
Number of Channels4S/2M