Bennett 3000 Spec 300 Series Instruction Manual Dispenser Operation
32
SUGGESTED SETUP SEQUENCE
The software program for each new dispenser shipped from the factory is pre-programmed with the default settings in some of the Menu
Codes. Make sure the initial setup menu codes are programmed before testing any dispenser operations. Failure to do so may lead to
difficulty getting the dispenser to operate properly.
INITIAL SETUP
Sides = 2, Grades = 1, Hoses = 1, Tier = 1
Pricing – For each hose and 1 or 2-tier pricing
Communication Type (Current Loop, Stand Alone, RS485,
Generic Current Loop, Fleet RS485)
Dispenser Address (Only used for Generic Current Loop & RS485)
0 = Only one dispenser on the communications
loop
Meter (Electronic) Calibration
REMAINING DISPENSER SETUP
Remaining Dispenser Setup
Meter Value – Amount for each meter
Programming Selections Viewer
Decimal Location – For other than U.S. Standard
No Flow Time Out ( International Purposes Only)
Slow Flow Amount – Control for Prepay Sales
Volume Allocation for a sale at a pump (International Use Only)
Pre-Charge, Idle, Last Sale, and Handle State Timer
Pre-Charge = 2 seconds, Last Sale = 30, Idle = 15,
Handle State = 0
Price Display – Control Operation
0 = Flashing, 0 = Dash, Flip = 0
Fleet System – Interface Compatibility
Motor Delay – Suction Pumps
.010 gallons or .10 liters
Rounding or Truncating the Sale Amount (International Use Only)
1 = Rounding the Sale Amount
1 = Access allowed without manager password
ATC – Petroleum Commodity Group
Pulse Output – Pulse Unit, Pulse Ratio, and Pulse Speed (PPS)
End Condition Prepay Sale
Marina Pulser Enable Delay
Proportional Valve (Start of Sale or End of Prepay / Preset Sale
Start of Sale = 35 %, End of Prepay Sale = 35 %
Unit of Measure - (International Purposes Only)
1 = Gallons, 1 – Decimal position 3 places