Bennett 3000 Spec 300 Series Instruction Manual Service & Troubleshooting
68
ERROR CODES
Error codes are displayed when there is a fault condition in the dispenser. In the event of an error, a message will be displayed
on the side of the dispenser where the error occurred. Any error message will shut down the sale but not disable the pump. To
clear an error message simply lower the handle or put the nozzle back in the boot and remove the nozzle again. To view the
error history log refer to Diagnostic Code 2 for more information. Note: Repair the problem that may have caused the error
first and then clear the message. If an error message continues to be displayed, please contact Bennett Technical Support at 1-
800-423-6638.
Continued on the next page…
The automatic temperature compensation probe reads less than -30
C
The automatic temperature compensation probe reads less than +40
C
Reverse Pulser – Inactive Pulser Turning Forward or Backwards
Detected Pulser A Rotating Backwards
Detected Pulser B Rotating Backwards
Detected Pulser C Rotating Backwards
Detected Pulser D Rotating Backwards
Pulser A Error Same State Transition Limit Exceeded
Pulser A Next State Transition Limit Exceeded
Pulser A Lead Channel Failed
Pulser A Lag Channel Failed
Grade A was Active when the Lower CPU Stopped Responding
Pulser B Same State Transition Limit Exceeded
Pulser B Next State Transition Limit Exceeded
Pulser B Lead Channel Failed
Pulser B Lag Channel Failed
Grade B was Active when the Lower CPU Stopped Responding
Pulser C Same State Transition Limit Exceeded
Pulser C Next State Transition Limit Exceeded
Pulser C Lead Channel Failed
Pulser C Lag Channel Failed
Grade C was Active when the Lower CPU Stopped Responding
Pulser D Same State Transition Limit Exceeded
Pulser D Next State Transition Limit Exceeded
Pulser D Lead Channel Failed
Pulser D Lag Channel Failed
Grade D was Active when the Lower CPU Stopped Responding
Detected Pulser A Rotating When Not Allowed
Detected Pulser B Rotating When Not Allowed
Detected Pulser C Rotating When Not Allowed
Detected Pulser D Rotating When Not Allowed
Grade E was Active when the Lower CPU Stopped Responding
Blend ratios sent from the console does not match the dispenser ratio.
Mailbox has exceeded its message limits.
Not Calibrated or Bad Checksum
E-Cal Constant Out of Range Error
Vapor Vacuum – Interlock Error
One or more electromechanical totalizer output counters are corrupted.
E-Cal Switch is in unsealed position and a normal sale started.
Vapor Vacuum – Side 1 Error – Fast Flow or Over Current