Bennett 3000 Series Spec 300 Instruction Manual Product Introduction
5
SECTION 2: PRODUCT INTRODUCTION
This manual covers the 3000 Series Spec 300 Electronic Commercial and Retail Dispensers and Pumps with 719 electronics. For
programming information, please refer to the 719 Electronic CPU Technical and Dispenser Programming Manual. Contact Bennett Pump
Technical Support for questions at 1-800-423-6638.
FEATURES
STANDARD
Products .................................................................................................................................................................................. Up to 2 Products
Hoses .............................................................................................................................................................................. Up to 2 Hoses Per Side
Unit Type ............................................................................................................................................................................. Straight Grade Only
Hydraulics ............................................................................................................................................................................. Remote or Suction
*
Standard Flow Rate ................................................................................................................................................ 23 gpm / 87 lpm (Remote)
................................................................................................................................................................................... 18 gpm / 68 lpm (Suction)
Heavy Duty Flow Rate ............................................................................................................................................... 24 gpm / 91 lpm (Suction)
Inlet / Outlet .............................................................................................................................1-1/2” (3.2 cm) dia NPT / 1” (2.54 cm) dia NPT
Protocol ........................................................................................................................ Bennett Current Loop / Generic Current Loop / RS485
BIG FUELER
Products .................................................................................................................................................................................. Up to 2 Products
Hoses .............................................................................................................................................................................. Up to 2 Hoses Per Side
Unit Type ............................................................................................................................................................................. Straight Grade Only
Hydraulics ............................................................................................................................................................................. Remote or Suction
Flow Rate .............................................................................................................................................................. 60 gpm / 230 lpm (Remote)
................................................................................................................................................................................. 40 gpm / 150 lpm (Suction)
Inlet / Outlet .................................................................................................................................. 2” (5 cm) dia NPT / 1-1/4” (4.4 cm) dia NPT
Protocol ........................................................................................................................ Bennett Current Loop / Generic Current Loop / RS485
SPECIFICATIONS
DIMENSIONS
Low Hose Dimensions (height x width x depth) ......................................................................... 60” x 30 x 20 (152.4cm x 76.2cm x 50.8 cm)
High Hose Dimensions (height x width x depth) ........................................................................ 88 x 32 x 20 (223.5cm x 81.3cm x 50.8 cm)
ENVIRONMENTAL REQUIREMENTS
Operang and Storage Temperature .............................................................................................................. -40
C to +65
C / -40
F to +185
F
Operang Humidity .................................................................................................................................................. 0 to 95% Non-Condensing
Storage Humidity ................................................................................................................................................. 30% to 70% Non-Condensing
POWER REQUIREMENTS
CAUTION: OPERATING THE REMOTE DISPENSER OR SUCTION PUMP AT VOLTAGES AT OR ABOVE THE REQUIRED 120/240VAC
IS NOT RECOMMENDED! FAILURE OR DAMAGE TO THE ELECTRONIC EQUIPMENT CAN OCCUR.
AC Power Input, Electronic ........................................................................................................... Universal Input 85-270 Volts A.C. 50/60 Hz.
External DC Power Supply Outputs ................................................................................................ +5VDC 100mA Max, +12 VDC 100mA Max.
DC Power Supply Outputs .............................................................................................. +24 VDC 1.0 Amps Max., +5VDC Isolated 50mA Max.
Nickel-Cadmium Battery Output ........................................................................................................................ +10.8VDC, 40 Milliamp Hours
Voltage ............................................................................................................................................................................. 120/240VAC 50/60Hz
*
Flow rates are “nominal” under ideal test conditions without accounting for system restrictions such as hanging hardware. Actual flow rates will vary
depending on conditions of installation.
Big Fueler Remote and Suction are nominal with one hose active with Master and Satellite in simultaneous flow with 1-1/2” valve.
Valance not included.