Control unit
EN
- 28 -
9.4
3RD
LEVEL PROGRAMMING
The following table gives the 3rd level functions and the single parameters.
= DEFAULT value set in factory.
= parameter value set during installation: must be indicated if DEFAULT value is modi ed.
NOTES:
· , , , :Output polarity
Output polarity: The outputs can be con gured as N.O. or N.C. but, in the event of a blackout the contacts open anyway.
·
:Velocity selection input
By enabling this parameter bar speed can be adjusted via the PDM input
()
, or it is possible manages the color of the cap for report the free
seats in the parking systems
().

If the PDM is activated and parameter enabled the barrier moves at a speed equal to 60% of maximum speed, both when opening and
closing.

The PDM manages the RED/GREEN color of the cap and report the free seats in the parking systems (see paragraph 10)
·
:Advance electric lock disengagement
This parameter adjusts the delay between electo-lock deactivation and engine start , to allow the resetting of the residual magnetism of the
electro lock.
·
:Advanced setup
This parameter enables the use of special con gurations for speci c necessities.

N/A.

Controlled entry and automatic exit (see paragraph 13).
· : UPS
UPS TYPE
Square-wave Internal detector, UPS input not connected
UPS with sinusoidal or quasi-sinusoidal wave form, with
dedicated output for signaling the absence of power net
Connect mains failure output to UPS input
Pure-sinusoidal wave UPS with dedicated output for signaling
the absence of power net
Use 230Vac relais, coil connected to mains supply, close contacts to UPS input
· Boom locking device con guration:
To use the boom locking device, connect the enabling contact to OUT2 or OUT3 or OUT4 or OUT5 and set the corresponding
parameter ,,  or  to . Set advance electric lock disengagement ( -3nd level)
Par Function Settable data

Advanced setup
(see notes after the table)
: no advanced setup

: N/A
: controlled entry and automatic exit

PDM dynamic input polarity
: input N.O.

: input N.C.




Output 2 polarity
Output 3 polarity
Output 4 polarity
Output 5 polarity
(see notes after the table)
: N.O.

: N.C.

Advance electric lock
disengagement
(see notes after the table)
: 0,5s - : 1s - : 1,5s - : 2s - : 2,5s - : 3s


Opening speed (%)
 - (ATM 90°, ATM 180°)

 - (MAXIMA ULTRA 35, Carbon)

 - (MAXIMA ULTRA 68)


Closing speed (%)
 - (MAXIMA ULTRA 68, ATM 90°, ATM 180°)

 - (MAXIMA ULTRA 35, Carbon)


Speed selection input
(see notes after the table)
: Disabled

: Enabled
: MAXIMA ULTRA 36 cap lights for parking function

Swinging boom sensor input
(see notes after the table)
: swinging boom not mounted or disabled

: swinging boom sensor mounted and activated N.C.

Exiting the menu/saving Pressing the “F” key, the programming menu is quit and the changes saved.