6
July 2020
Installation, Operation and Maintenance Manual
MAN616_EAC Rev. 5
Section 2: Installation
Installation
2.3 Assembling the Actuator Onto the Valve
2.3.1 Types of Assembly
For coupling to the valve, the housing is provided with a ange with threaded holes
according to Bif standard tables (SCN6200; SCN6200-1; SCN6201; SCN6201-1).
The number, dimensions and diameter of the holes are made in accordance with ISO 5211,
but for actuator models 0.3 to 6 the holes are drilled on the centreline in order to allow
an easier assembly of an intermediate ange, when required. This intermediate ange
(or spool-piece) can be supplied when the valve ange cannot directly match the actuator
ange in its “standard” conguration. For the biggest actuator models, the actuator ange
can be machined in accordance with the valve ange dimensions.
The yoke has bored with keyways for coupling to the valve stem, the dimensions of which
are according to Bif standard tables SCN6200* and SCN6201*.