Operating instructions FK 23 Installation
6.066.98.5.10.05 en 4 - 3
4
Measures for suppressing interference:
With severely contaminated mains supplies (e.g. when "thyristor-controlled systems" are
used) measures must be taken on-site to suppress interferences, e.g.:
– A separate supply line must be planned for Bizerba machines
– In problem cases, install capacitive decoupled isolating transformers or other sup-
pressors into the supply mains prior to Bizerba machines
4.3 Start-up
Initial start-up as well as instructions on how to operate, clean, maintain and service the
machine are initially provided by the responsible Bizerba service department or by a Bizer-
ba specialist.
Machine can only be operated if the saw door is closed.
Start test run, check running direction, switch on machine.
Press <I> (green) on the membrane keypad.
The lamp lights up (white) and the drive is in operation.
Fig. 5: Transport direction
Observe saw blade at the cutting point.
Saw blade and saw tooth direction
should run from top to bottom.
If the direction is incorrect, have the po-
larity reversed by Bizerba Customer
Services or professional electrician.
Switching the machine off
Press <O> (red) on the membrane keypad.
The machine is switched off.
Wait for 5 seconds before switching it on again.
4.4 Placing out of operation
If the machine is not going to be used for a longer period of time:
Switch off machine.