Operating instructions VS12D /C /-R /-V /-
V/R
Installation
6.083.98.5.10.10 en 4 - 3
4
CAUTION Incorrect supply voltage!
Damage of electric components, fire hazard.
– Do not connect the machine to the power supply if the power sup-
ply data does not correspond to the machine's connection values.
Mains data must be identical.
– Inform Bizerba Customer Service.
Installation of power supply provided by customer
Installation of the power supply to connect our machines must be carried out in accord-
ance with country-specific regulations and the terms and conditions derived thereof. These
essentially include the recommendations of at least one of the following commissions:
– International Electro-technical Commission (IEC)
– European Committee for Electro-technical Standardization (CENELEC)
The machine has been built according to Protection Type I and has to be connected to the
protective conductor.
Measures for suppressing interference:
With severely contaminated mains supplies (e.g. when "thyristor-controlled systems" are
used) measures must be taken on-site to suppress interferences, e.g.:
– A separate supply line must be planned for Bizerba machines
– In problem cases, install capacitive decoupled isolating transformers or other sup-
pressors into the supply mains prior to Bizerba machines
4.3 Start-up
Initial start-up as well as instructions on how to operate, clean, maintain and service the
machine are initially provided by the responsible Bizerba service department or by a
Bizerba specialist.
4.3.1 Switching the slicer on
Press the green key <I>.
White lamp goes on.
The blade motor is turning.
The display becomes active.
Carriage, depositing table and depositing arm move in their initial position.
4.3.2 Switching the machine off
Press <O> (red). (reduced operating force)