38
button as well. When this command is executed, the “Local” button will be disabled.
Command syntax: SYSTem:RWLock
Parameter: None
SYSTem:INTerface
This command is used to select the communication interfaces.
Command syntax:SYSTem:INTerface <USB|RS232>
5.6 TRIGGER Subsystem
TRIGger[:IMMediate]
This command is used to create a trigger signal. It will give a trigger signal in BUS trigger source
mode. The function is the same as command *TRG.
Command syntax: TRIGger[:IMMediate]
Parameter: None
Related commands: *TRG
TRIGger:SOURce
This command is used to select the trigger source. Power supply can receive trigger signals
directly from front panel by pushing “Trigger” button or receive from a BUS trigger signal using
*TRG command.
Command syntax: TRIG:SOURce <mode>
Parameter: MANUAL|BUS
Query syntax: TRIGger:SOURce?
Return parameter: MANUAL|BUS
5.7 SOURCE Subsystem
[SOURce:]OUTPut[:STATe]
This command is used to control the output state of the power supply.
Command syntax: [SOURce:]OUTPut [:STATe] <bool>
Parameter: 0|1|ON|OFF
Query syntax: [SOURce:]OUTPut[:STATe]?
Return parameter: 0|1
OUTPut:TIMer
This command is used to set the state of the output timer.
Command syntax: OUTPut:TIMer[:STATe] <bool>
Parameter: 0|1|OFF|ON