EasyManua.ls Logo

BK Precision PVS10005 User Manual

BK Precision PVS10005
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Model: PVS10005, PVS60085, PVS60085MR
High Power Programmable DC
Power Supply
USER MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the BK Precision PVS10005 and is the answer not in the manual?

BK Precision PVS10005 Specifications

General IconGeneral
Output Current0-5 A
Number of Outputs1
Display TypeLCD
Weight4.5 kg (9.9 lbs)
Current Resolution1 mA
Load Regulation (CV)≤ 0.01% + 2 mV
Line Regulation (CV)≤ 0.01% + 2 mV
Temperature Coefficient≤ 100 ppm/°C
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Input Voltage100 - 240 VAC, 50/60 Hz
Current Accuracy0.1% + 5 mA
HumidityUp to 80% RH, non-condensing
CoolingFan

Summary

Safety Summary

Grounding and Atmosphere Safety

Details proper grounding and avoiding hazardous atmospheres.

Operational Restrictions

Guidelines on critical applications, live circuits, and unauthorized modifications.

General Information

Product Overview

Introduces the B&K Precision PVS series power supplies and their features.

Getting Started

Input Power and Fuse Requirements

Specifies AC input voltage, frequency, and fuse information.

Front Panel Operation

Configure Voltage/Current Output

Instructions for setting output voltage and current values.

Remote Sense Operation

Explains local and remote sense configurations for accurate output.

CONFIG Menu Settings

Configures output limits, protection modes (OVP, OCP, OPP, CV/CC).

Program Function

Storing, recalling, and running programmed test sequences.

Remote Operation

Interface Configuration

Setup for USB, RS-232, GPIB, RS-485, and Ethernet interfaces.

SCPI Common Subsystem

Details SCPI commands organized by function subsystem.

Multi-Unit Programming Commands

Commands for controlling multiple power supplies in a chain.

Calibration

Voltage Calibration

Instructions for calibrating the output voltage.

Current Calibration

Instructions for calibrating the output current.

OVP Calibration

Procedure for calibrating overvoltage protection.

OCP Calibration

Procedure for calibrating overcurrent protection.

Troubleshooting Guide

General Troubleshooting

Answers common questions about power-up and operation.

Specifications

Output Ratings and Regulation

Details output voltage, current, power, and regulation specs.

Programming and Readback Accuracy

Accuracy specifications for programming and readback functions.

Limited Three Year Warranty