87
4.6 Non-SCPI Remote Commands
These commands are used for compatibility with old model power
supplies
Command
Description
ADDR <NR1 | ?>
Set or return the GPIB address
BEEP <Bool | ?>
Set or return beep 0=OFF, 1=ON
CLR
Clear protection status
CURRent <NRf | ?>
Set or return output current value
ERRor?
Return error message
IOUT?
return the measured output current
ISET <NRf | ?>
Set or return output current value
LOCK <Bool>
Set keyboard lock state
MODEL?
Return model name
OCP <Bool>
Set over-current protection state
OISET <NRf | ?>
Set or return over-current protection value
OPP <Bool>
Set over-power protection state
OPSET <NRf | ?>
Set or return over-power protection value
OUT <Bool | ?>
Set or return output state
OVP <Bool>
Set over-voltage protection state
OVSET <NRf | ?>
Set or return over-voltage protection value
STATUS?
Return status of the machine
VERsion?
Return firmware version number
VOLTage <NRf | ?>
Set or return output voltage value
VOUT?
Return the measured output voltage
VSET <NRf | ?>
Set or return output voltage value