6 Troubleshooting Guide
Below are some frequently asked questions and answers. Please check
if any apply to your power supply before contacting B&K Precision.
General
Q: I cannot power up the power supply.
- Check that the power cord is securely connected to the AC input
and there is live power from your electrical AC outlet.
- Verify that the AC power coming from the mains contains the
correct voltage. The power supply can accept a specific range of
AC input voltages. Refer to section 2.1.
Q: How do I set up the supply to run in constant current mode?
- The supply is a CV/CC power supply that automatically crosses over
from CV to CC upon a load which draws current at the current limit
(ISET). Therefore, it is dependent on the load. For example, if ISET
is configured as 1 A, the load must draw 1 A before the supply will
go into CC mode.
Q: How come my display voltage is lower than the voltage I set?
- This is often because of the resistances from the test leads/wires
connected between the supply and the DUT (device under test),
which causes a drop in voltage. To minimize this drop, use remote
sense terminals to compensate and output a more accurate
voltage to the DUT.
Q: I cannot set voltage at the maximum rating.
- This may be that the set voltage is outside of the voltage maximum
limit. Refer to section 3.6 under ā€œOutput Limit SettingsError!
Reference source not found.ā€ to verify and configure the limits.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BK Precision PVS10005 and is the answer not in the manual?

BK Precision PVS10005 Specifications

General IconGeneral
BrandBK Precision
ModelPVS10005
CategoryPower Supply
LanguageEnglish

Related product manuals