MNS-BB Software User Guide
-124-
The output can be filtered with the help of “Show Commands”.
E.g., Type Syntax: show log informational where “informational” is the <option> will show only
informational log entries.
----------------------------------------------------------------------------------------------
Severity Date Time Log Description
----------------------------------------------------------------------------------------------
I 21-09-2001 11:18:18 AM Rajesh Rajesh is now on line
I 21-09-2001 11:18:18 AM Server1 network enabled on 192.168.1.16
Here is the List of System Events:
Subsystem
Description
Severity
SNTP client started I
SNTP client stopped..disabled by user I
SNTP client stopped..server not configured I
SNTP Request timed out I
SNTP Retrying.. I
DEVICE System started I
DEVICE Network Stack not yet configured I
SNMP Snmp.snmpEnableAuthenTraps is set to enabled A
SNMP Snmp.snmpEnableAuthenTraps is set to disabled A
PRTMR Enabled by user monitor = x , sniffer = y I
PRTMR Disabled by user I
VLAN Type set to port I
VLAN Type set to mac I
VLAN Type set to tag I
VLAN Type set to none I
VLAN Pvlan: port based vlan started I
VLAN Pvlan: default vlan is modified I
VLAN Tvlan: Tag based vlan started I
TCP/IP Failed to initialize the interface x F
BRIDGE Bridge init failed for ethx F
BRIDGE Bridge enable for ethx failed F
DEVICE IP address a.b.c.d configured I
DEVICE subnetmask a.b.c.d configured I
DEVICE Default gateway a.b.c.d configured I
DEVICE Switch rebooted by user I
SNMP System.sysName configured A
SNMP System.sysLocation configured A
SNMP System.sysContact configured A
DEVICE Port x enabled A
DEVICE Port x disabled A
CLI Manager login at console I
CLI Operator login at console I
CLI Manager password changed I
CLI Operator password changed I
SNMP read community string changed I
SNMP write community string changed I
SNMP trap community string changed I
RMON rising alarm trap sent to a.b.c.d by alarm entry X I
RMON falling alarm trap sent to a.b.c.d by alarm entry X I
SNMP authentication failure trap sent to a.b.c.d I
SNMP Trap receiver a.b.c.d added I
SNMP Trap receiver a.b.c.d deleted I
DEVICE No saved system logs I
DEVICE Failed to read saved system logs D