11.2 Time output management menu
Programming by PC software allows the time zone differential of each output to be set with
respect to the local time.
This menu can be used to view all the time outputs, modify their status (Start/Stop) and
congure the DHF distribution in Init mode.
To go to the master clock time output management menu,
validate the option in the technician menu with the key.
The following screen is displayed :
On this screen you can start or stop the NTP distribution.
The programming is carried out by software. See NTP programming in appendix 1, page 42.
Important: the NTP distribution service must be started rst from the PC software.
Validate with the key. The following screen is displayed :
You can view the different options and change the values using the and keys.
You can go through the different outputs by validating using the key.
The placing of a DHF output in “INIT” status is active for 4 hours before return to START mode
(The init mode display alternates with the normal display during this period).
This menu can be used to set the power of the DHF output
with a choice of 25mW / 125mW (by default) / 500mW and
assign the system address from 1 to 4 (2 by default).
The buzzer mode allows you to activate a buzzer on the secondary transmitters in order to
identify them.
Use the key to move on to the next parameter:
Choice of status (“Start”/“Stop”).
Circuit stopping must be conrmed.
Use the key to return to the previous screen. or
NTP : START ú
ok
DHF 03 : INIT ú
125mW channel:2 ok
Time outputs ok
IP setting õ
Caution, STOP mode ok
on DHF output C
Caution, STOP mode ok
on NTP output C