61
Appendix I : NTP programming
IP function programming
The programming is carried out in 2 steps.
1 – Program the IP output (parameters supplied by the network administrator)
from the technician menu of the master clock (see page 38).
2 – Software conguration.
Start the PC software and then load the USB backup of your Sigma M.
In the menu, select “Time outputs” and “NTP server client”.
The master clock is an NTP client
On this NTP Client screen, it is possible to choose the mode of transmission of
the time signal.
Broadcast : the Sigma receives the time sent to all the products in the
network.
Multicast : the Sigma receives the time sent only by the address on which the
server transmits.
Unicast : the Sigma receives the time sent by a few selected NTP server IP
addresses.