6 - Troubleshooting
Problem
The screwing by push
pull is not working
correctly
The Push pull sensor has to be calibrated
Damaged mandrel thread
Switch off the battery and install it again
Replace the mandrel following the
instructions
Problem in the motor
Check the motor idle rotation by pressing
the Reset button
The setting cycle is not
proceeding
The setting conditions are not fullfilled
• Ensure that the Push pull screwing has
been done
• Change the condition for allowing the
setting launch
The quality of the
setting is not correct
The automatic
unscrewing is not
proceeding
The display screen
doesn't turn on
The RIVKLE
®
thread is damaged
after setting
The bulge of the RIVKLE
®
is not
well formed
The RIVKLE
®
head is not in contact
against the support after setting
The RIVKLE
®
turns on the support
• Adjust the position of the anvil following
the instructions.
• Excessive setting force. Check the
setting force value range in the
catalogue of the RIVKLE
®
• Damaged mandrel thread. Replace
the mandrel following the instructions.
• Thickness incompatible with the
RIVKLE
®
• The hydraulic pressure has not been
reached. Fill oil, following the instructions
• Setting force is too low. Check the
setting force value range in the
catalogue of the RIVKLE
®
• Repeat the setting test following the
instructions.
Make sure the RIVKLE
®
is push against
the support while setting
The hydraulic pressure has not been
reached.
Fill oil, following the instructions
RIVKLE
®
tapping or threading of the
damaged draw mandrel.
Replace the mandrel following the
instructions
Problem in the motor
Check the motor idle rotation by pressing
the Reset button
The battery is discharged Replace the battery with a charged one
The tool remains unused for several hours Remove the battery and reload it
Possible causes Solution