ACS 653, ACS 663 Service Manual
SP00D00624 2021-04-08Robert Bosch GmbH
105
Plumbing and Mechanical


The default vacuum time is 5:00 minutes. When the vacuum process begins, the vacuum pump is activated. After
a 5 second delay, the vacuum, high side and low side inlet solenoids are also activated. When the timer reaches
0 (zero), the vacuum process will stop.